RC-240
RC-240
Routine Parameters
Specialised Parameters
RC-240
Routine Parameters
Specialised Parameters
Specifications
- Category - Fully automatic chemistry analyzer
- Throughput-240 tests/hour (Without ISE) & 315 tests/hour (With ISE)
- Methodology-End point Fixed Time, Kinetic
- Reagent-Closed System
- Reagent Position-40
- Sample Position-40
- Minimum Reaction Volume-150 HL
- Carryover- < 0.005%
- Water consumption- Low to 5L/Hours
- Maximum Reaction Volume-5000 pl
- Principle-Colorimetri, Turbidimetry
- Sample Mode-Random Access, STAT sample priority
- Sample Volume-02-50pl,tep by 0.1 pl
- Sample Disk-40 positions
- Sample/Reagent Prob-One prob for sample and reagent with liquid level detection
- Reagent Volume-R1:150-450µL, R2:10-300µL,step by 0.1µL
- Reagent Disk-40 Reagent positions
- Reagent Bottles-Compatible with AU and hitachi bottles
- Mixer-High Polished nano material mixer
- Reaction Cuvettes-81 Cuvettes Semi-Permanent rigid UV special plastic cuvettes
- Wash Station-6-Step auto wash station
- Reaction Temperature-37+0.1'C
- Heater-Metal Thermostat for reaction disk
- Lamp-Halogen Tungsten lamp. 12V20W about 2000hours
- Filter-FMSS (Full-Sealed Matrix Spectrometric System)
- Wavelength-8 wavelengths:340,405,450,510,546,578,630,670nm
- Resolution-0.0001 Abs
- Linearity-0.0-3.5 Abs
- Accuracy-0.5A < + 0.2Abs. 1.0A +0.04Abs
- Stary Light0-> 4.5
- Stability-< 0.01 Abs/Hour
- CV- < 1.5%
- Half Band Accuracy-< +2nm
- Detector-Photodiode detector array
- Calibration Mode-One point linear, Two point linear, Multi-point Linear, Logit-4P, Logit-5P, Spline, Exponential Polynomial
- Calibration Curve-Calibration Curve auto check auto curve fitting
- QC Rule-L-J graph with Westgard multi rule Cumulative sum check Twin plot
- QC warning-Out of control auto warning data automatic record and analysis
- Operating system-Windows 7/10
- LIS Interface-Bi-LIS Interface
- Print Mode-Multi default formates User-defined formats
- PC Configuration-CPU 2.5GHz. memory 4GB, Hard disk 500GB
- Dimension-855(L) x 550(D) x 580(H)
- Power Supply-AC 100-240V 50/60Hz # 1 Hz.<350VA
- Net Weight 75 Kg
- Optional Parts-Barcode Reader ISE Module. PC with Touch Screen
Specifications
- Category - Fully automatic chemistry analyzer
- Throughput-240 tests/hour (Without ISE) & 315 tests/hour (With ISE)
- Methodology-End point Fixed Time, Kinetic
- Reagent-Closed System
- Reagent Position-40
- Sample Position-40
- Minimum Reaction Volume-150 HL
- Carryover- < 0.005%
- Water consumption- Low to 5L/Hours
- Maximum Reaction Volume-5000 pl
- Principle-Colorimetri, Turbidimetry
- Sample Mode-Random Access, STAT sample priority
- Sample Volume-02-50pl,tep by 0.1 pl
- Sample Disk-40 positions
- Sample/Reagent Prob-One prob for sample and reagent with liquid level detection
- Reagent Volume-R1:150-450µL, R2:10-300µL,step by 0.1µL
- Reagent Disk-40 Reagent positions
- Reagent Bottles-Compatible with AU and hitachi bottles
- Mixer-High Polished nano material mixer
- Reaction Cuvettes-81 Cuvettes Semi-Permanent rigid UV special plastic cuvettes
- Wash Station-6-Step auto wash station
- Reaction Temperature-37+0.1'C
- Heater-Metal Thermostat for reaction disk
- Lamp-Halogen Tungsten lamp. 12V20W about 2000hours
- Filter-FMSS (Full-Sealed Matrix Spectrometric System)
- Wavelength-8 wavelengths:340,405,450,510,546,578,630,670nm
- Resolution-0.0001 Abs
- Linearity-0.0-3.5 Abs
- Accuracy-0.5A < + 0.2Abs. 1.0A +0.04Abs
- Stary Light0-> 4.5
- Stability-< 0.01 Abs/Hour
- CV- < 1.5%
- Half Band Accuracy-< +2nm
- Detector-Photodiode detector array
- Calibration Mode-One point linear, Two point linear, Multi-point Linear, Logit-4P, Logit-5P, Spline, Exponential Polynomial
- Calibration Curve-Calibration Curve auto check auto curve fitting
- QC Rule-L-J graph with Westgard multi rule Cumulative sum check Twin plot
- QC warning-Out of control auto warning data automatic record and analysis
- Operating system-Windows 7/10
- LIS Interface-Bi-LIS Interface
- Print Mode-Multi default formates User-defined formats
- PC Configuration-CPU 2.5GHz. memory 4GB, Hard disk 500GB
- Dimension-855(L) x 550(D) x 580(H)
- Power Supply-AC 100-240V 50/60Hz # 1 Hz.<350VA
- Net Weight 75 Kg
- Optional Parts-Barcode Reader ISE Module. PC with Touch Screen
TRUST
Closed system with validated protocol for all specialised products
CONVENIENT
Barcoded* & smaller system pack reagents
AFFORDABLE
Affordable Cost for maximum specialised tests.
TOTAL SOLUTION
Liquid stable Control and calibrator are available with maximum assays.
CORRELATION